A practical reference on circadian rhythm: what it is, how it behaves, what the literature reports, and where the honest uncertainties sit.
This page was last updated on 2025-07-30 and is reviewed periodically as new material appears.
SR9009 is a synthetic small molecule studied as an agonist of the nuclear receptors REV-ERBα and REV-ERBβ, also called NR1D1 and NR1D2. These receptors help regulate circadian rhythms and metabolic gene programs. The compound was developed for laboratory research, not as an approved therapeutic. Its identity is distinct from steroid hormones and selective androgen receptor modulators. Scientific interest centers on how REV-ERB activation changes gene expression in cells and animal models.
At the molecular level, SR9009 binds the ligand-binding domain of REV-ERB and strengthens recruitment of corepressor proteins such as NCoR and HDAC3. This increases repression of target genes, including Bmal1 and other clock-controlled and metabolic genes. In rodent studies, such changes have been linked to altered lipid handling, glucose metabolism, and energy expenditure. The precise chain of events between receptor binding and whole-body effects remains an active area of research. Findings in animals do not automatically translate to humans.
Laboratory samples of SR9009 are typically supplied as a white to off-white powder. The compound dissolves readily in organic solvents such as dimethyl sulfoxide and ethanol, while its solubility in water is low. Because of this solubility profile, researchers often prepare concentrated stock solutions in an organic solvent before diluting them into aqueous assay buffers. Light exposure, moisture, and repeated freeze-thaw cycles can degrade many small molecules, so handling procedures usually aim to minimize these factors. Purity is commonly checked before use.
Storage conditions for research-grade SR9009 generally involve a freezer at approximately minus twenty degrees Celsius, sometimes lower for long-term preservation. Containers should remain tightly closed and protected from light. Desiccants may be used to limit moisture uptake. Solutions are often stored in aliquots to avoid repeated warming and cooling. Stability data for the compound under various conditions are limited, so laboratories typically follow supplier recommendations and verify performance through periodic analytical checks rather than assuming indefinite stability.
Identity and purity testing for SR9009 commonly uses liquid chromatography coupled with tandem mass spectrometry. This method separates the compound from matrix components and detects it by mass-to-charge transitions, providing sensitive and specific confirmation. Nuclear magnetic resonance spectroscopy can support structural identification, while high-performance liquid chromatography with ultraviolet detection may estimate purity. Because online products labeled as SR9009 may contain other substances or no active compound at all, independent verification is important in research settings. Certificates of analysis are useful but not a substitute for in-house testing.
| Property | Value | Notes |
|---|---|---|
| Chemical class | Synthetic small molecule | Studied as a REV-ERB agonist |
| Molecular formula | C20H24ClN3O4S | Reported for the neutral compound |
| Appearance | Off-white to pale yellow solid | Typical research-grade material |
| Solubility | Sparingly soluble in water | Soluble in solvents such as DMSO |
| Common synonyms | SR9009; Stenabolic | Stenabolic is an informal alias |
Analytical identification of SR9009 typically relies on liquid chromatography coupled with tandem mass spectrometry. In biological samples, researchers first separate the compound from matrix components using protein precipitation, liquid-liquid extraction, or solid-phase extraction. High-performance liquid chromatography with ultraviolet detection and nuclear magnetic resonance spectroscopy can support structural confirmation of reference materials. Because SR9009 is a small, relatively lipophilic molecule, reverse-phase columns and acidic mobile phases are common. Laboratories often include isotope-labeled internal standards to improve quantification and to correct for ion suppression.
Stability depends on physical form, temperature, light exposure, and solvent. Solid SR9009 is generally stored cold and dry, with protection from light to limit degradation. Dimethyl sulfoxide stocks are common for laboratory work, but repeated freeze-thaw cycles can reduce compound integrity. Aqueous solutions may be less stable than organic stocks, and the ethyl ester in the structure can be susceptible to hydrolysis under certain conditions. Researchers typically validate storage conditions and recheck purity before quantitative experiments, especially when using archived material.
Mean Absolute Relative Difference (MARD) is a standard metric used to evaluate the accuracy of continuous glucose monitoring systems, which gives the average amount a CGM sensor reading varies from the actual blood glucose. It is calculated by taking the average of the absolute relative differences between the glucose readings reported by the CGM system and corresponding reference measurements, typically obtained through laboratory analysis or blood glucose meters. A lower MARD value indicates greater accuracy, and it is commonly used in clinical research and regulatory evaluations to compare the performance of different CGM devices. It is also of note that MARD percentages can vary by person, even while using the same device. The accuracy of Dexcom CGM systems has steadily improved over time, as reflected in declining MARD values across successive generations. The original Dexcom STS, released in 2006, had a MARD of approximately 20.3%, while the Dexcom Seven, introduced in 2007, reduced this to around 17%. The Seven Plus had a slightly lower MARD of 16%. The G4 Platinum, launched in 2012, further improved accuracy with a MARD of 13.9%, followed by the G5 Mobile in 2015, which achieved 9%—the first Dexcom system to reach single-digit accuracy. in some users, however it also was found to be as high as 15%. The Dexcom G6, released in 2018, was similarly marketed with a MARD of 9%, although some studies found values exceeding 12% in certain individuals.
Even though the majority of plant cells have a cell wall that defines their morphology, their microfilaments can generate sufficient force to achieve a number of cellular activities, such as the cytoplasmic currents generated by the microfilaments and myosin. Actin is also involved in the movement of organelles and in cellular morphogenesis, which involve cell division as well as the elongation and differentiation of the cell. The most notable proteins associated with the actin cytoskeleton in plants include: villin, which belongs to the same family as gelsolin/severin and is able to cut microfilaments and bind actin monomers in the presence of calcium cations; fimbrin, which is able to recognize and unite actin monomers and which is involved in the formation of networks (by a different regulation process from that of animals and yeasts); formins, which are able to act as an F-actin polymerization nucleating agent; myosin, a typical molecular motor that is specific to eukaryotes and which in Arabidopsis thaliana is coded for by 17 genes in two distinct classes; CHUP1, which can bind actin and is implicated in the spatial distribution of chloroplasts in the cell; KAM1/MUR3 that define the morphology of the Golgi apparatus as well as the composition of xyloglucans in the cell wall; NtWLIM1, which facilitates the emergence of actin cell structures; and ERD10, which is involved in the association of organelles within membranes and microfilaments and which seems to play a role that is involved in an organism's reaction to stress.
=== Permanent hair removal === Electrology has been practiced in the United States since 1875. It is approved by the FDA. This technique permanently destroys germ cells responsible for hair growth by way of the insertion of a fine probe into the hair follicle and the application of a current adjusted to each hair type and treatment area. Electrology is the only permanent hair removal method recognized by the FDA.
Sources: en.wikipedia.org
=== Cardiovascular disease === Recent research suggests that patients with elevated basal levels of CRP are at an increased risk of diabetes, hypertension and cardiovascular disease. A study of over 700 nurses showed that those in the highest quartile of trans fat consumption had blood levels of CRP that were 73% higher than those in the lowest quartile. Although one group of researchers indicated that CRP may be only a moderate risk factor for cardiovascular disease, this study (known as the Reykjavik Study) was found to have some problems for this type of analysis related to the characteristics of the population studied, and there was an extremely long follow-up time, which may have attenuated the association between CRP and future outcomes. Others have shown that CRP can exacerbate ischemic necrosis in a complement-dependent fashion and that CRP inhibition can be a safe and effective therapy for myocardial and cerebral infarcts; this has been demonstrated in animal models and humans. It has been hypothesized that patients with high CRP levels might benefit from use of statins. This is based on the JUPITER trial that found that elevated CRP levels without hyperlipidemia benefited. Statins were selected because they have been proven to reduce levels of CRP. Studies comparing effect of various statins in hs-CRP revealed similar effects of different statins. A subsequent trial however failed to find that CRP was useful for determining statin benefit.
FAB is a relatively low fragmentation (soft) ionization technique and produces primarily intact protonated molecules denoted as [M + H]+ and deprotonated molecules such as [M - H]−. Radical cations can also be observed in a FAB spectrum in rare cases. FAB was designed as an improved version of SIMS that allowed for the primary beam to no longer cause damaging effects to the sample. The major difference between the two techniques is the difference in the nature of the primary beam used; ions vs atoms. For LSIMS, Cesium, Cs+ ions make up the primary beam and for FAB the primary beam is made up of Xe or Ar atoms. Xe atoms are used because they tend to be more sensitive than Argon atoms due to their larger masses and more momentum. For the molecules to be ionized by FAB, first the slow moving atoms (Xe or Ar) are ionized by colliding electrons. Those slow moving atoms are then ionized and accelerated to a certain potential where they develop into fast moving ions that become neutral in a dense cloud of excess natural gas atoms that make a flowing stream of high translational energy atoms. Although the exact mechanism of how the samples are ionized have not been fully discovered, the nature of its ionization mechanism is similar to matrix-assisted laser desorption/ionization (MALDI) and chemical ionization.
=== Analogues === α-Methyltryptophan (αMTP) and α-methyl-5-hydroxytryptophan (α-Me-5-HTP) are prodrugs of αMS which cross the blood–brain barrier and thus efficiently deliver αMS into the central nervous system. As a result, these compounds act as orally bioavailable false or substitute neurotransmitters for serotonin, and have been suggested as possible therapeutic agents in the treatment of disorders where serotonin is deficient. The O-methylated analogue of αMS, 5-MeO-αMT (α,O-dimethylserotonin; α,O-DMS), also readily enters the brain, and could be used for such purposes as well.
Sources: en.wikipedia.org
SR9009 is a synthetic research compound that activates the REV-ERBα and REV-ERBβ nuclear receptors. It is not an approved drug and has no established human therapeutic use. Most published biological data come from cell and rodent studies.
No. SR9009 is frequently mislabeled as a SARM in online discussions, but it does not target androgen receptors. Its known mechanism involves REV-ERB nuclear receptors and circadian-metabolic gene regulation.
Human clinical data are very limited. There is no approved human use, and safety and efficacy in people are not established. Most evidence comes from preclinical models, so effects observed in animals may not apply to humans.
Research-grade SR9009 is typically stored frozen at about minus twenty degrees Celsius, protected from light and moisture. Stock solutions are often kept in aliquots to avoid repeated freeze-thaw cycles. Specific storage conditions should follow the supplier's documentation.